top of page

Bathroom Exhaust Fan Cleaning in Toronto: Why Winter Mould Comes Back After You Scrub It

Writer: Desmond Breau
Desmond Breau
3 days ago
25 min read

There is a particular kind of frustration that belongs to November in Toronto. You spent an hour on the bathroom. You scrubbed the grout, you wiped down the caulk line, you got the grey speckling off the ceiling above the shower, and the room looked genuinely clean. Three weeks later the speckling is back in exactly the same place, in exactly the same pattern, and you are standing there wondering what you did wrong.

You did not do anything wrong. You cleaned the symptom. Almost every bathroom mould guide you will find online is a guide to cleaning the symptom: scrub this, spray that, try vinegar, try baking soda, try a stiffer brush. None of it is bad advice, exactly. It is just advice about the wrong object. Mould on a bathroom ceiling is not dirt that landed there. It is something that grew there, and it grew there because that spot stayed wet long enough for it to grow. Remove the growth and leave the wet, and you have changed nothing that matters.

Which brings us to the one piece of equipment in the room that is actually responsible for the wet, and that almost nobody cleans: the exhaust fan. In a Toronto winter, when you cannot open the window, that fan is the only way moisture leaves the bathroom at all. This article is about what it does, how to tell whether yours is big enough, how to clean it properly, where it has to vent, and what the research actually says about how long to leave it running. That last question has a more interesting answer than you might expect.

Bright minimalist Toronto bathroom with blue tiles, a glass shower and a clean white sink, the kind of room where winter moisture collects

Why Bathroom Mould Comes Back After You Clean It

Health Canada is unusually blunt about this, and the sentence is worth reading twice. In its guidance on addressing moisture and mould indoors, it states that unless the cause of the moisture problem has been identified and solved, mould will reappear. It goes further and turns the observation into a diagnostic: mould that comes back after cleaning is usually an indication that the source of moisture has not been removed.

So the recurrence is not a cleaning failure. It is information. A patch of mould that returns is telling you, fairly precisely, that the spot it returns to is still getting wet and still staying wet. The same guidance notes that mould will begin to grow in an area with excessive moisture within 48 hours, which is a short enough window to explain why a bathroom can look clean on Sunday and faintly grey again by the middle of the month.

It is also worth being clear about what mould is not. Health Canada's residential indoor air quality guideline for moulds says that mould growth requires the presence of nutrients, an adequate temperature, and a sufficient amount of water, and that fungal growth usually results from a moisture problem. Of those three requirements, the only one you control in a bathroom is the water. You cannot remove the nutrients, because soap scum, skin cells and the paper facing on drywall are all food. You are not going to make the room cold. Water is the whole lever.

That is the reason this article is about a fan rather than a cleaning product. We have made the same argument from the other direction in our guide to basement mould in Toronto, where the moisture source is condensation on cool below-grade surfaces rather than a hot shower. The surface is different, the physics is identical, and so is the conclusion: whoever controls the moisture controls the mould.

What the Fan Actually Does, and Why a Toronto Winter Makes It the Only Exit

A shower puts a remarkable amount of water into the air of a small room in a short time. Health Canada lists daily indoor activities such as showering or bathing, washing clothes or cooking among the main indoor moisture sources, and notes that moisture accumulates indoors when it cannot be vented outside. That last clause is the whole story. The water does not disappear when the mirror clears. It either leaves the building or it finds a cool surface and condenses on one.

In July you have options. Open the window, open the door, let the house breathe. From roughly November through March in Toronto you have one option, because opening a bathroom window in February is not a ventilation strategy, it is a heating bill. The fan becomes the only deliberate moisture exit in the room, and whether it works is no longer a comfort question. It is the difference between a bathroom that stays sound and one that grows a new crop every few weeks.

There is a second, less obvious reason winter is harder, and it is a point about air pressure rather than temperature. CMHC describes a heated house as being much like a chimney, and says that all winter a heated house is trying to push air through the top floor ceiling into the attic. Warm air rises, leaks out at the top, and pulls replacement air in low down. That upward current is constant through the heating season, and it carries bathroom moisture with it into ceiling cavities and attics, which is exactly where you do not want it.

Readers of our article on radon testing in Toronto will recognise that current under its technical name, the stack effect. It is the same mechanism, running in the same months, doing two different kinds of damage: pulling soil gas in at the bottom of the house and pushing shower moisture out at the top. One heating season, one piece of physics, two separate problems to manage.

The summer version of this problem is genuinely different, and we have treated it separately in our guide to summer humidity in Toronto. In August the moisture is arriving from outdoors and the answer involves air conditioning and dehumidifiers. In January the moisture is being generated indoors and the answer is extraction at the source. Treating the two seasons the same way is one of the more common mistakes in Toronto homes.

The 30 to 50 Per Cent Target, and the Window Test That Replaces a Hygrometer

Health Canada's advice on humidity is consistent across its indoor air pages: maintain relative humidity between 30 and 50 per cent, using a dehumidifier as necessary. It specifically suggests reaching for a dehumidifier if moisture is condensing on cold surfaces such as window panes, or if relative humidity is above 50 per cent. A hygrometer is the direct way to know, and Health Canada describes it as an inexpensive tool sold at most hardware stores.

But notice the alternative buried in that same sentence, because it is free and it is specific. Condensation on window panes is itself the indicator. If the inside of your windows is beading up on a cold morning, the air in that room holds more water than the room can handle, and no amount of scrubbing is going to change that. Health Canada adds three habits that follow directly: keep window coverings open so warm air reaches the glass, because heavy curtains or blinds can trap the cold and moisture and cause condensation; and dry your window frames and sills daily to keep water from dripping and causing mould to grow.

After 48 years of cleaning Toronto homes through winter, that is the single most reliable tell we know. A bathroom with a fogged window at nine in the morning is a bathroom that will have mould by spring, whatever the ceiling looks like today.

How Long Should the Fan Run? Three Authorities, Three Answers

This is the question every homeowner actually asks, and it is the one place where the published guidance genuinely does not agree with itself. We think it is worth laying the disagreement out rather than picking one number and pretending it is settled.

Health Canada's moisture and mould guidance says at least 30 minutes. Its instruction is to keep the exhaust fan running for at least 30 minutes after a shower or bath. That is the longest figure of the three, and it comes from the page specifically concerned with preventing mould rather than with general air quality.

Health Canada's general mould page says a few minutes. On the page aimed at reducing humidity, moisture and mould, the same department advises letting kitchen and bathroom fans run for a few minutes after you finish cooking or showering. Same authority, same subject, a dramatically shorter interval.

The Home Ventilating Institute says 20 minutes. HVI, the industry body that certifies fan airflow ratings, recommends keeping the fan running for 20 minutes after bathroom use, and recommends a timer for turning the fan off automatically.

So: a few minutes, 20 minutes, or at least 30 minutes, depending on which page you land on. None of these sources is wrong and none is careless. They are answering slightly different questions. A few minutes clears the visible steam. Twenty minutes is an engineering figure built around a sized fan moving a known volume of air. Thirty minutes is the precautionary number from the people whose concern is specifically that mould does not grow.

Our practical resolution, for a Toronto house in the heating season, is this. Turn the fan on before you get in rather than after you get out, so it is already moving air while the moisture is being generated. Leave it running 20 to 30 minutes after you are done. Then stop guessing and let the room tell you: if the mirror and the window are dry and the walls are not tacky half an hour later, your run time is long enough. If they are not, it is not, and that is true no matter which guideline you were following.

The reason the longer figure tends to win in winter is that a sealed house has nowhere else to put the water. In summer, moisture that the fan misses can still diffuse out through an open window somewhere else in the house. In February it cannot. It migrates to the coldest surface available and condenses there, which in a Toronto bathroom usually means the window reveal, the exterior-wall corner behind the toilet, or the ceiling above the shower head.

Is Your Fan Big Enough? Sizing, Air Changes and Sones

A clean fan that is too small for the room is still too small for the room, so sizing comes before cleaning. HVI's published guidance sets bathroom ventilation rates based on roughly eight air changes per hour, which translates into a rule of thumb that is easy to apply with a tape measure: one CFM per square foot of bathroom floor area, where CFM is cubic feet of air per minute.

The bands HVI publishes are these. For a bathroom under 50 square feet, a 50 CFM rating is recommended as a minimum. Between 50 and 100 square feet, use one CFM per square foot, so a seven by ten foot bathroom calls for a 70 CFM fan and an eight by five foot bathroom calls for 40 CFM. Above 100 square feet, the calculation switches from floor area to fixtures: 50 CFM for the toilet, 50 for a shower, 50 for a bathtub, and 100 for a jetted tub. A large bathroom with a tub, a separate shower and an enclosed toilet therefore totals 150 CFM, which you can meet either with one 150 CFM fan drawing air across the room or with three 50 CFM fans placed at each wet point.

Two details in that guidance matter more than they look. First, HVI notes that higher ventilation rates are also acceptable and will have a minimal energy impact, which means erring upward costs you very little. Second, rooms with ceilings over eight feet may need more ventilation than the floor-area rule suggests, because the rule is really about volume and the shortcut assumes a standard ceiling.

And then there is the detail nobody thinks about: the air has to be able to get in. HVI's guidance says to undercut bathroom doors so makeup air can enter, with at least three quarters of an inch of clearance from the floor. A powerful fan behind a door sealed to the carpet by a thick draught stopper cannot move air, because there is nothing to replace what it removes. It will hum, and it will accomplish very little. HVI also advises placing exhaust points over or near the shower or tub, keeping them away from supply registers so air travels across the room, and giving an enclosed toilet area its own fan or operable window.

Why a Loud Fan Is a Fan Nobody Uses

Fan noise is measured in sones, and HVI publishes a scale that makes the number intuitive. Four sones is about the volume of a television. Three is typical office noise. One sone is roughly a refrigerator, and half a sone is rustling leaves. For quiet bathroom ventilation, HVI says the fan should be rated at one sone or less.

This is not an audiophile concern, it is a compliance concern, and it is the quietly decisive factor in whether a household gets the 20 to 30 minutes of run time discussed above. A fan at three or four sones is genuinely unpleasant to sit under, so people switch it off the moment they step out of the shower, which is precisely the half hour that matters. A fan at one sone or less gets left on, because nobody notices it. If you are replacing a fan and you only remember one specification, remember that one.

HVI also points out that airflow ratings are worth verifying rather than trusting. Its certified label indicates independent performance testing, and HVI tests submitted products, approves the data before labelling, and periodically buys products off the market to retest them. A box claiming a CFM figure with no certification behind it is a marketing number.

How to Clean a Bathroom Exhaust Fan, Step by Step

A bathroom fan collects a felt-like mat of dust, lint and airborne skin cells on the grille and on the impeller behind it. That mat does not merely look bad. It restricts the opening the air has to pass through, which means a 70 CFM fan stops being a 70 CFM fan, and it loads the motor, which is why an old fan sounds like it is working hard. The whole job takes about fifteen minutes and needs a screwdriver, a vacuum with a brush attachment, a cloth and dish detergent.

Top view of a white circular bathroom air vent grille showing the discolouration that builds up when an exhaust fan is never cleaned

1. Kill the power at the panel, not at the wall switch. Broan-NuTone's installation and maintenance instructions are explicit that power should be switched off at the service panel before servicing or cleaning. A wall switch can be miswired, and you are about to put your fingers inside a housing that contains a live motor. This is the step to not improvise on.

2. Remove the grille and the grille trim. Most residential grilles are held by two spring clips that you squeeze inward, not by screws. Pull the grille down a couple of centimetres, pinch the clips, and it comes away in your hand.

3. Wash the grille with mild detergent only. The manufacturer's instruction is that plastic parts can be cleaned with mild detergent, such as dishwashing liquid, then dried with a soft cloth. It is equally explicit about what not to use: do not use abrasive cloth, steel wool pads or scouring powders. Those scratch the plastic, and a scratched grille holds dust far better than a smooth one, so an abrasive clean makes the next clean harder. Warm water and dish soap in the sink, a soft brush for the slots, and let it dry completely before it goes back up.

4. Vacuum the housing with the dusting brush attachment. With the grille off, the manufacturer's instruction is to gently vacuum the interior with the dusting brush attachment. Work around the impeller blades and the inside of the housing. The word gently is doing real work there: the impeller is light plastic on a balanced shaft, and forcing it sideways is how a quiet fan becomes a noisy one.

5. Leave the motor alone. Broan-NuTone states that the motor is permanently lubricated and never needs oiling. Oiling it is a popular piece of folk maintenance and it accomplishes nothing useful. If the bearings are unusually noisy, the documented remedy is to replace the blower assembly, not to lubricate it.

6. Reassemble, restore power, and check that it actually pulls. Hold a single square of toilet tissue flat against the grille with the fan running. If the fan holds it there unaided, air is moving. If the tissue drifts off, you have either a blocked duct, a stuck backdraft damper, a dead motor or a fan that was never big enough, and cleaning the grille was never going to fix any of those.

The Humidity Sensor Is the Part People Destroy

Many newer Toronto bathrooms have a humidity-sensing fan, which switches itself on when moisture rises and runs on a timer afterwards. These are excellent, because they solve the run-time problem without requiring anyone to remember anything: the timer controls how long the fan remains on after the humidity in the room returns to the set point.

They also contain the one component in the whole assembly that ordinary cleaning will ruin. Broan-NuTone's instruction for the sensor is to clean it with a dry dustcloth, a toothbrush, or light vacuuming, and then, in capitals, not to use cleaning sprays, solvents or water on or near the sensor. If you have been spraying an all-purpose cleaner up into the fan opening because it was convenient, that is very likely why your automatic fan stopped behaving automatically. Dry methods only, and keep the spray bottle on the counter.

This is the sort of detail where our own working model helps rather than hinders. Custom Maids does not supply the cleaning products for a job, the client does, which means the household already owns and controls exactly what gets used in each room. A note on the caddy saying dry cloth only for the fan is all it takes, and it is a conversation that happens before anyone sprays anything. We made the same argument in more detail in our article on cleaning product fumes and winter indoor air, where the question was what you are breathing rather than what you are breaking.

How Often This Needs Doing

Neither Health Canada nor the manufacturer sets a cleaning interval in months, and we are not going to invent one, because the right interval depends entirely on how hard the fan works. A single-occupant condo bathroom and a four-person family bathroom with two showers a day are not the same machine.

Use the same test the rest of this article runs on, and let the room set the schedule. Pull the grille down and look at it whenever you clean the bathroom properly. If the slots are visibly furred, it is due. If the tissue test fails, it is overdue. If the mirror is still fogged half an hour after a shower when it used to clear in ten minutes, the fan has lost airflow and the cause is almost always the mat on the grille and impeller. In a busy household in the heating season, that point tends to arrive sooner than people expect.

Where Your Fan Vents Matters More Than How Clean It Is

Here is the uncomfortable part. A spotless fan that discharges into your attic is worse than a dirty fan that discharges outdoors, because all it is doing is moving the moisture problem somewhere you cannot see it and cannot clean it.

Every authority on this agrees, which is rare enough to be worth noting. Health Canada's guidance says an exhaust fan should be installed in each bathroom, and that fans should be checked so they are vented to the outside and not into the attic. Broan-NuTone's instructions state flatly that ducted fans must always be vented to the outdoors. CMHC's homeowner guidance on attics says bathroom fans need to be ducted outside. Three different kinds of organisation, one sentence.

The reason is the point about winter air that CMHC makes in the same document: in winter, the cold outside air cannot hold much humidity or carry moisture away from the attic. So moisture dumped into an attic in January does not ventilate out. It condenses on the first cold surface it meets, which is the underside of the roof sheathing. CMHC describes the result in plain terms: the whole attic or part of it may be dripping with condensation or covered with frost, and attributes both to warm, moist air leaving the house and entering the attic. The signs it tells homeowners to look for include water stains or evidence of mould on the sheathing, rafters or trusses, and it warns that prolonged wetness will rot out the roof sheathing. A roof-ducted exhaust fan is also listed among the spots where ice dams form.

If you can see the duct, there are four things worth checking from a stepladder, and all of them come from the installation guidance rather than from opinion. The duct should be the diameter the fan was designed for, which on a typical residential unit is four inch round. The route should be the shortest, straightest duct routing possible for best performance, because every elbow and every sag costs airflow. The first and last eighteen inches should be rigid or stretched straight rather than left as a concertina of flexible duct. And in an unheated space the duct should be solid metal, insulated, and sloped so condensation inside it drains to the outside rather than back toward the fan. CMHC adds one specific warning that is easy to get wrong with good intentions: do not wrap the insulation in plastic, as this will trap moisture.

Checking the far end is the other half of the job, and it is the half that gets skipped. Go outside and find the hood or the roof cap. If the damper flap is painted shut, frozen shut, stuffed with a bird nest or buried under a drift, the fan inside has been running against a closed door all winter. We go through the same reasoning about the rest of a home's ductwork in our article on duct cleaning in Toronto, and the conclusion there applies here too: with ventilation hardware, what the air can actually do matters far more than what the surfaces look like.

The Backdraft Warning on the Last Page of the Manual

There is a safety warning printed in every bathroom fan manual that almost nobody reads, and in a tight Toronto house in winter it deserves more attention than it gets. Broan-NuTone's warning, printed under a heading about reducing the risk of fire, electric shock or injury, is that sufficient air is needed for proper combustion and exhausting of gases through the flue of fuel-burning equipment, in order to prevent backdrafting.

The mechanism is straightforward once it is spelled out. An exhaust fan removes air from the house. That air has to be replaced from somewhere. In a leaky older house it arrives through a hundred small gaps and nobody notices. In a well-sealed house, with the stack effect already pulling air upward and several exhaust appliances running at once, the easiest replacement path can become a chimney or a flue, reversing its flow and drawing combustion gases back into the house instead of sending them out.

This is not a reason to run the fan less. It is a reason to know what else is running. The combination worth being aware of is a bathroom fan, a kitchen range hood on high and a clothes dryer all working at the same time in a sealed house with a natural-draught gas appliance. If your bathroom fan makes the furnace room smell different, or a door that normally swings freely suddenly wants to stay shut, those are both pressure symptoms and they are worth a conversation with a heating contractor rather than a cleaning schedule. Broan-NuTone also notes that unusual noise or a smell of smoke from the fan itself means disconnecting the power supply and contacting the manufacturer.

When to Stop Cleaning and Call Someone

Health Canada puts numbers on this, which is useful, because the alternative is guessing with a sponge in your hand. The thresholds are set by the size and number of patches.

Small: one to three patches, each under one square metre. Roughly ten square feet or less per patch. A homeowner can clean this with proper precautions.

Medium: more than three patches, or patches over one square metre but under three. Three square metres is about thirty-two square feet. Health Canada says expert assessment is recommended here, though the area may be cleaned up using proper precautions.

Extensive: a single patch larger than three square metres. Health Canada recommends that a qualified professional assess and clean up large areas of mould. This is not a cleaning job and it is not ours either.

For the areas you can handle, the precautions Health Canada lists are specific: safety glasses or goggles, a disposable N95 respirator and household gloves; plastic sheeting taped over walls and ceiling to isolate the area; HEPA vacuuming before and after cleaning; and cleaning with water and dish detergent. On drywall, use a damp cloth rather than a wet one so the board does not get soaked. Keep susceptible people out of the room entirely, which Health Canada identifies as children, seniors and people with medical conditions such as asthma and severe allergies.

Two instructions in that guidance contradict a great deal of what circulates online, so they are worth stating plainly. The first is about bleach: Health Canada's instruction is not to use bleach to clean up mould, and its cleaning method for washable surfaces is to scrub using a cloth with an unscented soap solution and dry completely and quickly. The second is about paint, and it is the sentence that answers the most common shortcut in rental housing: painting only temporarily hides the problem.

It is also worth knowing why air testing is not the answer it sounds like. Health Canada's residential indoor air quality guideline states that the variety of mould species and the differences between individuals preclude the derivation of exposure limits, and that without such limits, results from tests for the presence of fungi in air cannot be used to assess risks to the health of building occupants. There is, in its words, no safe limit for mould. Its recommendations are to control humidity, diligently repair water damage, and thoroughly clean any visible or concealed mould growth, and those recommendations apply regardless of the species found. A lab report naming the species does not change what you have to do about it.

The health case for taking it seriously is in the same guideline. Health Canada considers that mould growth in residential buildings may pose a health hazard, and its literature review found that exposure to indoor mould is associated with an increased prevalence of asthma-related symptoms such as chronic wheezing, with two cohort studies finding significant associations between home dampness and the risk of developing asthma. Its practical pages list eye, nose and throat irritation, coughing and mucus build-up as common, and note that some airborne moulds can cause severe lung infections in people with very weakened immune systems.

What a Toronto Renter Can Actually Require

If you rent, the fan is not your equipment, and Toronto's property standards bylaw is more specific on this point than most tenants realise. Chapter 629 of the municipal code sets out that there must be adequate ventilation, meaning fresh air flow, in all areas of a building. The sentence that follows is the one worth writing down: every ventilation system or unit must be regularly cleaned, kept in good repair, and maintained in good working condition at all times.

That is a maintenance obligation on the owner, and it covers the bathroom fan as a ventilation unit. A fan that is furred shut, disconnected, or venting into a ceiling cavity is not in good working condition, whatever else is true about the unit.

The process the City describes is sequential, and following it in order matters. Speak to your landlord or property manager first and submit the request in writing, which gives you a dated record. If the issue is not resolved in a timely manner, contact 311, online or by phone. There is no fee to make a complaint, and bylaw enforcement officers review complaints and investigate validated ones. For multi-tenant houses the City sets response times: urgent requests within 24 hours and other requests within seven days. For a condo rental, the City's direction is to talk to the landlord first and then contact 311 if the problem is not addressed.

None of that is a reason to stop cleaning your own grille, which you are entitled to do and which takes fifteen minutes. But if the airflow is gone because the duct was never connected properly, that is a repair, not a chore, and the obligation sits with the owner.

The Habits That Lower the Moisture Load

A correctly sized, clean, properly vented fan handles a normal bathroom. What overwhelms one is the total amount of water the room has to deal with, and several of the biggest contributors are habits rather than hardware. Health Canada's own recommendations include a few that take seconds and make a measurable difference.

Soft grey towels folded on a shelf against a white tiled bathroom wall, part of the moisture routine that keeps mould from returning

Squeegee the walls. Health Canada's instruction is to squeegee and dry the walls around the bathtub and shower after use. It feels fussy for about a week and then becomes automatic, and it removes a large share of the water before the fan has to deal with it as vapour.

Hang wet towels where air moves. A folded damp towel on a rack against an exterior wall in an unventilated bathroom is a slow-release humidifier. Spread them out, and run the fan while they dry rather than only while you shower.

Open the window coverings. As above: heavy curtains or blinds can trap the cold and moisture and cause condensation. Letting warm room air reach the glass is free and it keeps the coldest surface in the room above the dew point for longer.

Seal around the tub and sink. Health Canada's advice is to seal tubs and sinks tightly so water does not leak into walls, which is where the mould you never see grows. A failed caulk line at the tub surround is one of the commonest hidden moisture sources in Toronto bathrooms, and re-caulking is cheap.

Use the range hood properly too. The kitchen is the other big moisture producer, and Health Canada's finding on it is the most striking number in all of its ventilation guidance: cooking on the back burner with the range hood on high reduces particles and gases by more than 80 per cent compared with slower fan speeds. The same principle applies in the bathroom. Extraction at the source, at full speed, beats dilution across the whole house.

It is also worth knowing what will not save you, because it is widely sold as if it would. Health Canada's position on air cleaners is that air cleaning is rarely effective on its own and should be combined with better ventilation and reducing the source. A portable purifier in a bathroom filters particles out of the air. It does not remove a single gram of water from the room, and water is what the mould needs.

If a bathroom has already gone past the point where a weekly clean keeps up, that is usually a sign that the backlog needs clearing once before a routine can hold. That is the situation our deep cleaning service in Toronto exists for, and it is also the right moment to deal with the fan, the caulk line and the duct in one pass rather than three.

Sources and Research

The moisture and mould guidance in this article, including the instruction to keep the exhaust fan running for at least 30 minutes after a shower or bath, the 48-hour window in which mould begins to grow, the statement that mould will reappear unless the moisture cause is solved, the direction that fans be vented to the outside and not into the attic, and the squeegee, window-covering and caulking advice, comes from Health Canada's Guide to addressing moisture and mould indoors. The 30 to 50 per cent relative humidity range, the few-minutes fan interval, the hygrometer note, the patch-size thresholds of one and three square metres, the N95 and plastic-sheeting precautions, the HEPA vacuuming instruction, the advice that bleach is not needed, and the list of susceptible groups come from its page on reducing humidity, moisture and mould.

The statements that there are no derivable exposure limits for mould, that air tests cannot be used to assess occupant health risk, that the recommendations apply regardless of species, and the asthma and dampness findings from the reviewed literature are from Health Canada's Residential Indoor Air Quality Guideline: Moulds. The finding that cooking on the back burner with the range hood on high reduces particles and gases by more than 80 per cent compared with slower speeds, and the position that air cleaning is rarely effective on its own, are from Improve indoor air quality in your home.

The fan sizing figures are published by the Home Ventilating Institute: the eight air changes per hour basis, the one CFM per square foot rule, the 50 CFM minimum for small bathrooms, the per-fixture totals of 50 CFM for a toilet, shower or bathtub and 100 for a jetted tub, the 20-minute run time, the door undercut and makeup-air requirement, and the ceiling-height caveat come from its pages on bathroom ventilation and bathroom exhaust fans, which are also the source for the sone scale, the one-sone target for quiet operation, and the description of how HVI certifies and retests airflow ratings.

The cleaning and maintenance instructions, including the mild-detergent and no-abrasives rule for the grille, the dusting-brush vacuuming of the housing, the dry-cloth-only rule for the humidity sensor, the permanently lubricated motor, the four inch round duct, the shortest and straightest routing, the rigid first and last eighteen inches, the requirement to vent outdoors, the combustion-air and backdraft warning and the service-panel power-off instruction, are from Broan-NuTone's installation and maintenance guide for its humidity-sensing ventilation fan. The attic consequences of venting indoors, the chimney analogy for a heated house, the frost and condensation on roof sheathing, the solid-metal insulated sloped duct detail, the warning not to wrap duct insulation in plastic, and the ice-dam note come from CMHC's About Your House guidance on attic venting, attic moisture and ice dams. The ventilation maintenance obligation, the 311 complaint route, the absence of any fee and the multi-tenant response times are from the City of Toronto's property standards information.

A Word from Custom Maids Toronto

(Sponsor of the Article)

Custom Maids has been cleaning Toronto homes for more than 48 years, which means we have seen a great many bathrooms in February. The pattern is consistent: the rooms that stay sound are not the ones cleaned hardest, they are the ones where the moisture has somewhere to go.

We also do something unusual that happens to matter here. Custom Maids does not supply the cleaning products for a job, the client does. You decide exactly what comes into your home, which is why a household with asthma, a scent sensitivity or a humidity-sensing fan that must never be sprayed can set those rules once and have them followed every visit.

If your bathroom has reached the point where a regular clean is not keeping up, that is worth a conversation rather than another hour with a brush. You can see how we work, and what a visit covers, at Custom Maids Toronto.

Frequently Asked Questions

How long should I run my bathroom fan after a shower?

The published guidance ranges from a few minutes to at least 30 minutes, depending on the source. For a Toronto house in the heating season we would run it 20 to 30 minutes after you finish, and turn it on before you get in rather than after you get out. Then verify: if the mirror and window are dry half an hour later, your run time is long enough.

Does cleaning the fan actually stop bathroom mould?

On its own, not necessarily. Cleaning restores the airflow the fan was designed to move, which is usually the missing piece. But if the fan is undersized, vents into the attic, or the duct is crushed or blocked at the outside hood, cleaning the grille will not fix the moisture problem. Health Canada is clear that mould returns whenever the moisture source remains.

What size fan does my bathroom need?

The Home Ventilating Institute's rule is one CFM per square foot of floor area, with 50 CFM as the minimum for bathrooms under 50 square feet. So a seven by ten foot bathroom wants about 70 CFM. Above 100 square feet you add by fixture instead: 50 CFM each for the toilet, shower and bathtub, and 100 for a jetted tub.

Can I spray cleaner inside the fan opening?

Not if the fan has a humidity sensor. The manufacturer's instruction is to clean the sensor with a dry dustcloth, a toothbrush or light vacuuming, and explicitly not to use cleaning sprays, solvents or water on or near it. For the grille itself, mild detergent such as dishwashing liquid is fine, washed in the sink rather than sprayed in place.

Should I use bleach on bathroom mould?

Health Canada's instruction is not to use bleach to clean up mould. Its method for washable surfaces is to scrub with a cloth and an unscented soap solution, then dry completely and quickly. Bleach can lighten the stain without addressing the growth, and painting over it only temporarily hides the problem.

How much mould can I clean myself?

Health Canada's thresholds are by patch size. One to three patches each under one square metre, about ten square feet, can be handled by a homeowner with proper precautions. More than three patches, or patches between one and three square metres, warrant expert assessment. A single patch larger than three square metres should be assessed and cleaned by a qualified professional.

Is it a problem if my fan vents into the attic?

Yes, and it is the most serious fault on this list. Health Canada, CMHC and the fan manufacturers all say the same thing: the fan must discharge outdoors. CMHC notes that in winter the cold outside air cannot carry moisture away from an attic, so the water condenses on the roof sheathing, where prolonged wetness will rot it out.

Why does my bathroom fan sound so loud?

Either it is a high-sone unit, or it is loaded with dust, or the impeller is out of balance. Fan noise is rated in sones, and HVI recommends one sone or less for quiet operation, which is about the level of a refrigerator. If a clean fan is still noisy at the bearings, the documented remedy is to replace the blower assembly rather than oil the motor, which is permanently lubricated.

My landlord will not fix the bathroom fan. What can I do?

Toronto's property standards require adequate ventilation and require that every ventilation system or unit be regularly cleaned, kept in good repair and maintained in good working condition at all times. Ask your landlord in writing first. If it is not resolved in a timely manner, contact 311, online or by phone. There is no fee to make a complaint.

Will an air purifier help with bathroom moisture?

No. A purifier filters particles from the air and removes no water from the room, and water is what mould needs. Health Canada's position is that air cleaning is rarely effective on its own and should be paired with better ventilation and reducing the source. In a bathroom that means the exhaust fan, not a filter.

Custom Maids

The GTA’s First and Original

Home Cleaning Service

Serving Toronto, Vaughan, Markham and Richmond Hill

Since 1978, Custom Maids has been a trusted presence in the GTA. Over five decades we have cleaned more than five million homes and continue to set the standard for professional home cleaning in the Greater Toronto Area.

Get Social With Us

2026 marks the 48th anniversary of the founding of Custom Maids. With decades of experience behind us, we continue to serve thousands of households in Toronto, Vaughan, Richmond Hill and Markham with the same care and attention that built our reputation. Our story is written quietly, in the homes we clean and the trust we earn every day.

Born in the GTA.  Canadian-Owned.  Trusted Since 1978.

bottom of page